Product Details:
Model Name/Number | SICAM_P50 |
Brand | Siemens |
Usage/Application | Industrial |
Phase | - Single-phase,three-phase balanced or unbalanced connection,four-wire connection |
Application Type | power monitoring and recording at MV and LV level. |
Display Type | Graphic |
Power meter device SICAM P50/55
SICAM P is a power meter for panel mounting with graphic display and background illumination, or for standard rail mounting, used for acquiring and/or displaying measured values in electrical power supply systems. More than 100 values can be measured, including r.m.s. values of voltages (phase-to-phase and/or phase-to ground), currents, active, reactive and apparent power and energy, power factor, phase angle, harmonics of currents and voltages, total harmonic distortion per phase plus frequency and symmetry factor, energy output, as well as external signals and states.
Functions
Application Areas
Power monitoring systems with SICAM P, a permanently installed system, enables continuous logging of energy-related data and provides information on operational characteristics of electrical systems. SICAM P helps identify sources of energy consumption and time of peak consumption. This knowledge allows to allocate and reduce energy costs.
The major application area is power monitoring and recording at MV and LV level. The major information types are measured values, alarms and status information.
The input modules work with external signals with a measurement range of DC 0 -20 mA. Mean values of all external analog channels as well as states of digital channels can be recorded and saved into the memory. All recorded quantities and binary state information can be read out and evaluated with the configuration software SICAM P Manager. Output modules can be used for conversion of any electrical quantity (current, voltage, etc.) into a DC 0 -20 / 4 -20 mA output signal, generation of impulses for metering, indication of limit value violations, as well as for switching operations.
Power Quality
Ensuring power quality in a phase of energy transition
Increasing power feed-in from renewable resources poses new challenges for municipalities and distribution system operators.
The stable supply of electric power is any grid operators top priority. To avoid fluctuations in power quality and prevent disturbances, grid monitoring, control, and automation systems need to be adapted and optimized across all voltage levels.
Power Generation
Maintaining control of distributed power producers
Ensuring grid stability is becoming increasingly complex.
The vast number of small distributed power producers calls for new strategies to ensure consistent power quality. Identifying, locating, and eliminating disturbances and faults as well as the flexible, quick balancing of power production and load consumption require integrated hardware and software solutions that work smoothly together.
Product Details:
Model Name/Number | SICAM_850 |
Brand | Siemens |
Usage/Application | Industrial |
Phase | Single,3 wire,4 wire system |
Application Type | Ensuring power quality in a phase of energy transition |
Display Size | Din rail,panel optional |
Display Type | Digital |
Type | multifunctional measuring device |
Siemens SICAM P850 power meter device
The SICAM P850 multifunctional measuring device is used for acquisition, visualization, evaluation and transmission of electrical measured variables such as alternating current, alternating voltage, frequency, power, harmonics etc. The measured variables can be output to a PC or system control via communication interfaces or shown on a display. In addition to the monitoring function, the SICAM P850 all-in-one device provides a recording function: measured values can be recorded in parameterizable time intervals with measurement and fault recorders.
Technical specification
Input measuring circuits
Measured variables
Communication interfaces and protocols
Operation and display
Time synchronization
Auxiliary voltage
Housing specification
Special features
Applications
The SICAM P850 device is used in single-phase as well as in three-wire and four-wire systems (with neutral conductor). The device is applied wherever comprehensive measurement of supply quality is necessary - at power utilities as well as in industry and trade sectors.
Power Quality
Ensuring power quality in a phase of energy transition
Increasing power feed-in from renewable resources poses new challenges for municipalities and distribution system operators.
The stable supply of electric power is any grid operator’s top priority. To avoid fluctuations in power quality and prevent disturbances, grid monitoring, control, and automation systems need to be adapted and optimized across all voltage levels.
Customer benefit
Product Details:
Model Name/Number | SICAM Q100 |
Brand | Siemens |
Usage/Application | Industrial |
Features | power quality standard EN 50160 |
PROTOCOL | IEC 61000-4-30 |
Inputs | 12 Binary inputs |
Outputs | 12 Binary Outputs |
Product Details:
Model Name/Number | SICAM P855 |
Brand | Siemens |
Usage/Application | Industrial |
Input measuring circuits | - 4x alternating voltage, 3x alternating current (max. 10A) |
Communication protocol | - Ethernet: MODBUS TCP, IEC 61850 Edition 2, Serial: Modbus RTU, IEC 60870-5-103 |
LED's | 4 |
Product Details:
Brand | Siemens |
Usage/Application | Laboratory |
Phase | Single |
Temperature Range | -25 to 70 Degree C |
Voltage | 220 V |
Frequency | 50 Hz |
Transducer SICAM T
SICAM T is a digital measurement transducer that allows the measuring of electrical quantities in electrical networks in a single unit. In industries, power plants and substations, transducers are especially used for measurand (e.g. current, voltage, power, phase angle, energy or frequency) assignment into further processing through analog outputs or communication interface for precise control, notification or visualization tasks.
Application Areas
Features
Highlights
Functions
Device type
Input and output circuits
Communication
Product Details:
Model Name/Number | SICAM Q200 |
Brand | Siemens |
Usage/Application | Industrial |
Inputs | 6 Binary Inputs |
Outputs | 6 Binary Outputs |
Protocol supported | - 2 x Ethernet (IEC61850, DNPP 3i and MODBUS TCP), MODBUS gateway/master, integrated switch, SNMPv3 |
Product Details:
Model Name/Number | SICAM MMU |
Brand | Siemens |
Usage/Application | Industrial |