Diagnostic Testing Of Transformer Motors Generator

Our Services
The he transformer also goes through some other tests, performed on it, before actual commissioning of the tra nsformer at site. The transformer testing performed before commissioning the transformer at site is called pre-commissioning test of transformer. These tests are done to assess the condition of transformer after installation and compare the test results of all the low voltage tests with the factory test reports. Type tests of transformer includes
  1. Transformer winding resistance measurement
  2. Transformer ratio test.
  3. Transformer vector group test.
  4. Measurement of impedance voltage/short circuit impedance (principal tap) and load loss (Short circuit test).
  5. Measurement of no load loss and current (Open circuit test).
  6. Measurement of insulation resistance.
  7. Dielectric tests of transformer.
  8. Temperature rise test of transformer.
  9. Tests on on-load tap-changer.
  10. Vacuum tests on tank and radiators.

Transformer Partial Discharge Measurement And Localization

Transformer Partial Discharge Measurement And Localization
  • Transformer Partial Discharge Measurement And Localization
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationIndustrial

On Line Testing

» Partial Discharge Measurement And Localization

» Thermography

» On Line Moisture Content Measurement

» Transformer Oil (Screening, DGA and Furan ) Test

Request
Callback
Yes! I am interested

SFRA Testing Sweep Frequency Response Analysis Measurement

SFRA Testing Sweep Frequency Response Analysis Measurement
  • SFRA Testing Sweep Frequency Response Analysis Measurement
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationIndustrial Use

Off Line Testing

» Dielectric Frequency Response Analysis [ DFR ]

 » Sweep Frequency Response Analysis Measurement

 » Capacitance And Tan Delta Measurement Of Transformer

 » Transformer Turns Ratio Measurement

 » Magnetic Balance Measurement

 » Excitation Current Measurement

 » Winding Resistance Measurement

 » Insulation Resistance And Polarization Index Measurement

 » OTI And WTI Meter Calibration

 » Functional Checking Of Protection Devices Like PRV, Buchoze Relay, MOG,OTI, WTI

Request
Callback
Yes! I am interested

Tan Delta Measurement Of Transformer

Tan Delta Measurement Of Transformer
  • Tan Delta Measurement Of Transformer
Ask For Price
Product Price :Get Latest Price

Off Line Testing

» Dielectric Frequency Response Analysis [ DFR ] 

» Sweep Frequency Response Analysis Measurement 

» Capacitance And Tan Delta Measurement Of Transformer 

» Transformer Turns Ratio Measurement 

» Magnetic Balance Measurement 

» Excitation Current Measurement 

» Winding Resistance Measurement 

» Insulation Resistance And Polarization Index Measurement 

» OTI And WTI Meter Calibration 

» Functional Checking Of Protection Devices Like PRV, Buchoze 

Relay, MOG,OTI, WTI 

Request
Callback
Yes! I am interested

Dry Ice Cleaning CO2 Cleaning

Dry Ice Cleaning CO2 Cleaning
  • Dry Ice Cleaning CO2 Cleaning
Ask For Price
Product Price :Get Latest Price

Product Details:

Type of Propertyon

Dry Ice Cleaning/CO2 Cleaning:

» Effective, Efficient and time saving cleaning of Electrical apparatus like 

Motors, Generators etc. 

» Dry Ice Cleaning or CO2 cleaning is a process where dry Ice (Solid form of carbon dioxide) is accelerated in a pressurized air stream and directed at a surface in order to clean it. 

 

Advantages of Dry Ice/CO2 Cleaning:

» It is a non-abrasive 

» It is Non-conductive cleaning method 

» Does not leave secondary contaminants such as dangerous solvents as dry ice sublimates at room temperature. 

» Saves downtime as the process is less time-consuming. 

 

 

Note: For Motors and Generators, our expertise does not stop at cleaning; we complete the job by applying right combinations of varnishes, resins and drying at appropriate temperatures. 

 

 

 

 

 

Request
Callback
Yes! I am interested

Partial Discharge Measurement

Partial Discharge Measurement
  • Partial Discharge Measurement
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
ApplicationLaboratory, Industrial

Online Mode

» Partial Discharge Measurement ( For All Switch-yard Equipment )

» Leakage Current Measurement ( Only For LA )

» Thermography ( For All MV/EHV Equipment )

Request
Callback
Yes! I am interested

Transformer Oil Condition Monitoring

Transformer Oil Condition Monitoring
  • Transformer Oil Condition Monitoring
Ask For Price
Product Price :Get Latest Price

Product Details:

Application/Usageon

Transformer Mineral Insulating Oil Condition

• Physical Parameters

» Appearance 

» Interfacial Tension 

» Flash Point 

» Pour Point 

» Density

» Kinematic Viscosity

 

Chemical Parameters

» Water Content

» Total Acid Number / Neutralization Value

» Sediments And Sludge

 

Electrical Parameters

» Breakdown Voltage / Dielectric Strength

» Specific Resistance / Resistivity

» Dielectric Dissipation Factor / Tan Delta

 

Request
Callback
Yes! I am interested

Dissolved Gas Analysis (DGA )

Dissolved Gas Analysis (DGA )
  • Dissolved Gas Analysis (DGA )
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationIndustrial Use

Transformer Internal Condition

» Dissolved Gas Analysis (DGA )

Request
Callback
Yes! I am interested

Furanic Compound Analysis

Furanic Compound Analysis
  • Furanic Compound Analysis
Ask For Price
Product Price :Get Latest Price

» Furanic Compound Analysis ( Furans )

 

• Other Special Test As Per Customer Requirement.

• Testing Packages as per IS/IEC/ASTM Standards.

Request
Callback
Yes! I am interested

Tomography For All MV/EHV Equipment

Tomography  For All MV/EHV Equipment
  • Tomography  For All MV/EHV Equipment
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
Testing TypeLeakage Testing

Online Mode

» Partial Discharge Measurement ( For All Switch-yard Equipment )

» Leakage Current Measurement ( Only For LA )

» Thermography ( For All MV/EHV Equipments )

Request
Callback
Yes! I am interested

Diagnostic Testing Of Motor & Amp; Generator

Diagnostic Testing Of Motor & Amp; Generator
  • Diagnostic Testing Of Motor & Amp; Generator
Ask For Price
Product Price :Get Latest Price

Product Details:

Type of MotorAC Motor

Online Mode

» Partial Discharge Measurement 

» Vibrations Spectrum Analysis 

» Thermography 

» Electrical Signature Analysis ( ESA ) 

» Current Spectrum Analysis

 

Off Line Mode

» Capacitance And Tan Delta Test

» Dielectric Discharge Test

» Partial Discharge Test

» I.R./P.I. Measurement

» HV DC Test

» RTD - Resistance And IR check

» Thermostat Resistance

» Diode Check

» Dielectric Frequency Response Analysis

» Motor Circuit Analysis ( MCA )

» Sweep Frequency Response Analysis

» Stator Rotor Winding Resistance

» Recurrent Surge Oscilloscope ( RSO )

» Rotor Winding Impedance

» Rotor Pole Drop Test

» Exciter/ PMG Tests

 

Off line Mode- for Generator

» Visual Inspection of Stator and Rotor

» Endoscopic Inspection

» EL-CID Test On Stator Core

» Wedge Tapping Test or Wedge Deflection Test

Request
Callback
Yes! I am interested

Vibrations Spectrum Analysis

Vibrations Spectrum Analysis
  • Vibrations Spectrum Analysis
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
ApplicationIndustrial Use

Online Mode

» Partial Discharge Measurement

» Vibrations Spectrum Analysis

» Thermography

» Electrical Signature Analysis ( ESA )

» Current Spectrum Analysis

Request
Callback
Yes! I am interested

Current Spectrum Analysis

Current Spectrum Analysis
  • Current Spectrum Analysis
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
ApplicationIndustrial Use

Online Mode

» Partial Discharge Measurement

» Vibrations Spectrum Analysis

» Thermography

» Electrical Signature Analysis ( ESA )

» Current Spectrum Analysis

Request
Callback
Yes! I am interested

Thermography Services For Motors & Amp; Generators

Thermography Services For Motors & Amp; Generators
  • Thermography Services For Motors & Amp; Generators
Ask For Price
Product Price :Get Latest Price

Product Details:

Testing Areaon

Online Mode

» Partial Discharge Measurement

» Vibrations Spectrum Analysis

» Thermography

» Electrical Signature Analysis ( ESA )

» Current Spectrum Analysis

Request
Callback
Yes! I am interested

Dielectric Discharge Test For motors

Dielectric Discharge Test For motors
  • Dielectric Discharge Test For motors
Ask For Price
Product Price :Get Latest Price

Off Line Mode

» Capacitance And Tan Delta Test 

» Dielectric Discharge Test 

» Partial Discharge Test

» I.R./P.I. Measurement

» HV DC Test

» RTD - Resistance And IR check

» Thermostat Resistance

» Diode Check

» Dielectric Frequency Response Analysis

» Motor Circuit Analysis ( MCA )

» Sweep Frequency Response Analysis

» Stator Rotor Winding Resistance

» Recurrent Surge Oscilloscope ( RSO )

» Rotor Winding Impedance

» Rotor Pole Drop Test

» Exciter/ PMG Tests

 

Request
Callback
Yes! I am interested

Dielectric Frequency Response Analysis

Dielectric Frequency Response Analysis
  • Dielectric Frequency Response Analysis
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationIndustrial Use

Off Line Mode

» Capacitance And Tan Delta Test

» Dielectric Discharge Test

» Partial Discharge Test

» I.R./P.I. Measurement

» HV DC Test

» RTD - Resistance And IR check

» Thermostat Resistance

» Diode Check

» Dielectric Frequency Response Analysis

» Motor Circuit Analysis ( MCA )

» Sweep Frequency Response Analysis

» Stator Rotor Winding Resistance

» Recurrent Surge Oscilloscope ( RSO )

» Rotor Winding Impedance

» Rotor Pole Drop Test

» Exciter/ PMG Tests

Request
Callback
Yes! I am interested

Circuit Breaker Testing

Circuit Breaker Testing
  • Circuit Breaker Testing
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
Testing Typeon

» Capacitance And Tan Delta Measurement

» Insulation Resistance Measurement

» Dynamic Contact Resistance Measurement ( DCRM )

» Static Contact Resistance Measurement ( CRM )

» Timing Measurement

» SF6 Gas Dew Point Measurement

» SF6 Gas Leakage Test

» Vacuum Interrupter Test ( VIDAR- Only For VCB )

» Functional Check ( Remote Trial )

Request
Callback
Yes! I am interested

Electrical Signature Analysis ( ESA )

Electrical Signature Analysis ( ESA )
  • Electrical Signature Analysis ( ESA )
Ask For Price
Product Price :Get Latest Price

 

Online Mode

» Partial Discharge Measurement

» Vibrations Spectrum Analysis

» Thermography 

» Electrical Signature Analysis ( ESA ) 

» Current Spectrum Analysis 

Request
Callback
Yes! I am interested

Recurrent Surge Oscilloscope ( RSO )

Recurrent Surge Oscilloscope ( RSO )
  • Recurrent Surge Oscilloscope ( RSO )
Ask For Price
Product Price :Get Latest Price

Product Details:

UsageIndustrial, Laboratory

Off Line Mode

» Capacitance And Tan Delta Test

» Dielectric Discharge Test

» Partial Discharge Test

» I.R./P.I. Measurement

» HV DC Test

» RTD - Resistance And IR check

» Thermostat Resistance

» Diode Check

» Dielectric Frequency Response Analysis

» Motor Circuit Analysis ( MCA )

» Sweep Frequency Response Analysis

» Stator Rotor Winding Resistance

» Recurrent Surge Oscilloscope ( RSO )

» Rotor Winding Impedance

» Rotor Pole Drop Test

» Exciter/ PMG Tests

Request
Callback
Yes! I am interested

Rotor Pole Drop Test

Rotor Pole Drop Test
  • Rotor Pole Drop Test
Ask For Price
Product Price :Get Latest Price

Off Line Mode

» Capacitance And Tan Delta Test

» Dielectric Discharge Test

» Partial Discharge Test

» I.R./P.I. Measurement

» HV DC Test

» RTD - Resistance And IR check

» Thermostat Resistance

» Diode Check

» Dielectric Frequency Response Analysis

» Motor Circuit Analysis ( MCA )

» Sweep Frequency Response Analysis

» Stator Rotor Winding Resistance

» Recurrent Surge Oscilloscope ( RSO )

» Rotor Winding Impedance

» Rotor Pole Drop Test

» Exciter/ PMG Tests

Request
Callback
Yes! I am interested
X

Explore more products



Reach Us
Piyush Rathi (Partner)
Office No. 9, Plot No. 53/54, Space Heights Sector 34
Panvel, Navi Mumbai- 410209, Maharashtra, India



Call Us

Share Us

F GT L


Send E-mailSend SMS